Technical Data
Electrical Specifications | ||
---|---|---|
Type No. | 96520118 | |
Rx Characteristics | ||
Frequency range | 1920-1980(2100MHz) | 2500-2570(2600MHz) |
Gain | 12dB±1dB | |
Gain Fluctuation |
0.6dB typ 1.5dB max |
|
Noise figure @25℃ | 1.5dB typ. | |
Return loss in by-pass mode | 15dB min | |
Return loss in normal mode | 18dB min | |
Max Input Power | <12dBm | |
Output 1–dB compression pint | 12dBm min | |
Insert loss in by pass mode @25℃ | 2.8dB typ | |
Tx Characteristics | ||
Frequency range | 2110-2170/2620-2690 | |
Insert loss @25℃ | ≤0.4 | |
Insert loss @(-40-+65℃) |
≤0.40. ≤0.8dB typ.,0.9dB max |
|
Return loss | ≥18 | |
Peak power | ≤200 | |
Intermodulation products in RX band | <-117dBm (2 Tx carriers at +43 dBm) (Power up) @BTS IM3 | |
Mechanical Specifications | ||
Dimensions, HxWxD (excluding connectors and mounting bracket) (mm) |
225x290x139 | |
Weight (including connectors and mounting bracket) (kg) | 11 | |
Packing Size(mm) | 440x285x199(2Pcs/box) | |
Connector Type | 4.3-10 Female | |
Color | Light Gray | |
Mounting | Wall mounting: with 4 screws (max. 8 mm diameter), Mast mounting: with additional clamp set | |
Material | Aluminium housing | |
Environmental Specifications | ||
Operational Temperature (°C) | -40~+60 | |
Operational Humidity (%) | ≤95 | |
Ingress Protection Class | IP67(Indoor and Outdoor) | |
MTBF | > 1,000,000 hours (per TMA) | |
EMC | According to ETS 300 342-3 | |
DC and Alarm Characteristics | AISG mode | |
Lightning Protection | 3kA; 10/350 μs pulse |