Technical Data
Electrical Specifications | |
---|---|
Type No. | 96520138 |
Rx Characteristics | |
Frequency range | 1710-1785 |
Gain | 12dB±1dB |
Gain Fluctuation | 1.5dB max |
Noise figure @25℃ | 1.6dB typ 1.85dB max . |
Return loss in normal mode | 18dB min |
Max Input Power | <12dBm |
Output 1dB compression pint | >12dBm min |
Insert loss in by pass mode @25℃ | 2.5dB typ., 2.8dB max |
Tx Characteristics | |
Frequency range | 1805-1880 |
Insert loss @25℃ | 0.50dB typ.,0.60dB max |
Return loss | ≥18 |
Average Power | 180W |
Peak power | ≤1600W |
Intermodulation products in RX band (2 Tx carriers at +43 dBm) | ≤-160dBc(Power up)@ANT IM3 |
≤-150dBc(Power up)@BTS IM3 | |
Mechanical Specifications | |
Dimensions, HxWxD (excluding connectors and mounting bracket) (mm) | 270x180x120 |
Weight (including connectors and mounting bracket) (kg) | 4.9 |
Packing Size(mm) | 424x240x210(2Pcs/box) |
Connector Type | DIN Female |
Color | Light Gray |
Mounting | Wall mounting: with 4 screws (max. 8 mm diameter), Mast mounting: with additional clamp set |
Material | Aluminium housing |
Environmental Specifications | |
Operational Temperature (°C) | -40~+65 |
Operational Humidity (%) | ≤95 |
Ingress Protection Class | IP67(Indoor and Outdoor) |
MTBF | > 1,000,000 hours (per TMA) |
EMC | According to ETS 300 342-3 |
DC and Alarm Characteristics | AISG mode |
DC supply | 10– 30 V |